DIMONDS® PP1838 Open-cell Polyurethane Foam System for Submarine Pipe Insulation
Description
DIMONDS® PP1838 is a two-components open-cell polyurethane foam system. This product is water based system. The product can be applied in submarine pipelines.
Physical Properties
Items | Units | DIMONDS® PP1838 | DIMONDS® ISO1800 |
Appearance | Colorless liquid | Brown liquid | |
Viscosity,25℃ | mPa.s | 200-500 | 150-250 |
Specific gravity,20℃ | g/ml | 1.05±0.05 | 1.24±0.01 |
Reaction Performance(by hands)
Items | Units | Specifications |
Cream time | sec | 10-20 |
Gel time | sec | 40-60 |
Track free time | sec | 60-80 |
Free rise density | Kg/m3 | 120-160 |
Foam Performances
Items | Units | Specifications | Test Standard |
Density | Kg/m3 | 160-240 | ASTM D1622 |
Compressive strength | MPa | ≥1.75 | ASTM D1621 |
Open cell content | % | ≥75 | ASTM D2856 |
The above testing data have been generated in lab or field conditions which are typical for this application. They are believed to be correct but data variations due to varying processing or ambient conditions can not be excluded. The customer remains responsible for making his own interpretation of data and suitability of the chemicals to his particular operation.
Handling and Storage
DIMONDS® PP1838 should be protected from moisture by keeping containers sealed when not in use. Drums have to be stored indoors to protect the material from water ingress, frost and direct heat from the sun. Under temperature conditions and in properly sealed containers, the storage life of the polyol is 6 months.
The optimum storage temperature should be 10-30℃.