DIMONDS® S1804LNG Blend Polyols for Spray Foam LNG Cryogenic Insulation

DIMONDS® S1804LNG Blend Polyols for Spray Foam LNG Cryogenic Insulation

Short Description:

Description DIMONDS® S1804LNG is a two-components, spray-applied, closed-cell polyurethane foam system. This product is premixed with HFC-245fa as foaming agent which designed specializing for cryogenic insulation engineering, such as tanks and large-scale pipelines etc. Typical Properties Item Unit DIMONDS® S1804LNG DIMONDS® ISO1800 Physical state By visual Transparent liquid Brown liquid Viscosity, 25℃ mpa.s 200-500 150-250 Gravity,20℃ g/ml 1.15±0.1 1.24±0.01 Reaction properties...


  • FOB Price: US $2.0 - 4.0/Kg
  • Min.Order Quantity: 1000 Kg
  • Supply Ability: 1000 MT per Month
  • Product Detail

    Product Tags

    Description

    DIMONDS® S1804LNG is a two-components, spray-applied, closed-cell polyurethane foam system. This product is premixed with HFC-245fa as foaming agent which designed specializing for cryogenic insulation engineering, such as tanks and large-scale pipelines etc.

    Typical Properties

    Item Unit DIMONDS® S1804LNG DIMONDS® ISO1800
    Physical state By visual Transparent liquid Brown liquid
    Viscosity, 25℃ mpa.s 200-500 150-250
    Gravity,20℃ g/ml 1.15±0.1 1.24±0.01

    Reaction properties (hand test)

    Item Unit Specification
    Cream time sec 3-6
    Gel time sec 10-20

    Recommended processing information

    Item Unit Specification
    Hose heat temperature 35-55
    Static pressure psi 1200-1600
    Dynamic pressure psi 1100 min
    Ambient temperature -5-50
    Ambient humidity RH % ≤70

    Foam properties

    Item Unit Specification Test standard
    Core density kg/m3 ≥40 ASTM D1622-08
    Thermal conductivity, 20℃ W/(m.k) ≤0.023 ASTM C518-10
    Tensile strength kPa ≥210 ISO 1926:2009
    Compressive strength kPa    ≥180 ASTM D1621-10
    Cohesion kPa ≥210 ASTM D1623-17
    Closed cell content     % ≥90 ASTM D6226
    Liner thermal expansion coefficient μm/(m·℃) ≤-100 ASTM E831-14
    Thermal stability-30, 24h-RT,2h-70℃,90%RH, 24h % ≤1.5 ASTM D2126-09
    Flammability   B1/B2 DIN 4102

    The above testing data have been generated in lab or field conditions which are typical for this application. They are believed to be correct but data variations due to varying processing or ambient conditions can not be excluded. The customer remains responsible for making his own interpretation of data and suitability of the chemicals to his particular operation.

    Handling and Storage

    DIMONDS® S1804LNG should be protected from moisture by keeping containers sealed when not in use. Drums have to be stored indoors to protect the material from water ingress, frost and direct heat from the sun. Under temperature conditions and in properly sealed containers ,the storage life of the polyol is 6 months and Isocyanate 12 months.

    The optimum storage temperature should be 10-25℃.

    Package

    220kg/drum for DIMONDS® S1804LNG and 250kg/drum for DIMONDS® ISO1800.