DIMONDS® B1862 Blend Polyols for PUR Block Foam

DIMONDS® B1862 Blend Polyols for PUR Block Foam

Short Description:

Description DIMONDS® B1862 is a compounded polyether polyol developed for block foam. It contains polyether polyol, silicone surfactant, catalysts and water. It can be applied to block foam. The foam can be applied for chemical industry, petrocheimcal field, LNG, LPG etc. Typical Properties Item Unit DIMONDS® B1862 DIMONDS® ISO1800 Physical state By visual Transparent liquid Brown liquid Viscosity, 25℃ mpa.s 400-800 150-250 Gravity,20℃ g/ml 1.20±0.05 ...


  • FOB Price: US $2.0 - 4.0/Kg
  • Min.Order Quantity: 1000 Kg
  • Supply Ability: 1000 MT per Month
  • Product Detail

    Product Tags

    Description

    DIMONDS® B1862 is a compounded polyether polyol developed for block foam. It contains polyether polyol, silicone surfactant, catalysts and water. It can be applied to block foam. The foam can be applied for chemical industry, petrocheimcal field, LNG, LPG etc.

    Typical Properties

    Item

    Unit

    DIMONDS® B1862

    DIMONDS® ISO1800

    Physical state

    By visual

    Transparent liquid

    Brown liquid

    Viscosity, 25℃

    mpa.s

    400-800

    150-250

    Gravity,20℃

    g/ml

    1.20±0.05

    1.24±0.01

    Reaction properties (hand test)

    Item

    Unit

    Specification

    Cream time

    sec

    40-70

    Gel time

    sec

    150-240

    Free rise density

    kg/m3

    26-28

    Processing informations

    Item

    Unit

    Specification

    Component temperature

    25±3

    Mold temperature

    45±3

    Dynamic pressure

    kPa

    130±10

    It is recommended to utilize high pressure foaming machinery. The chemicals should be adjusted to the correct temperature between 22-27℃ to ensure reactivity and viscosity suitable for processing.

    The mixing pressure has to be set for both components at 120-150 bar.

    The mould temperature recommended is 40-50℃ to guarantee good foam performances.


    Foam properties

    Item

    Unit

    Specification

    Test standard

    Overall density

    kg/m3

    ≥40

    ASTM D1622-08

    Thermal conductivity, 10℃

    W/(m.k)

    ≤0.023

    ASTM C518-10

    Compressive strength

    kPa   

    ≥200

    ASTM D1621-10

    Tensile strength

    kPa

    ≥270

    ISO 1926

    Closed cell content    

    %

    ≥90

    ASTM D6226

    Water absorb

    %

    ≤2

    ASTM C209-12

    Flammability

     

    B3

    DIN 4102

    The above testing data have been generated in lab or field conditions which are typical for this application. They are believed to be correct but data variations due to varying processing or ambient conditions can not be excluded. The customer remains responsible for making his own interpretation of data and suitability of the chemicals to his particular operation.

    Handling and Storage

    DIMONDS® B1862 should be protected from moisture by keeping containers sealed when not in use. Drums have to be stored indoors to protect the material from water ingress, frost and direct heat from the sun. Under temperature conditions and in properly sealed containers ,the storage life of the polyol is 6 months.

    The optimum storage temperature should be 10-30℃.


  • Previous:
  • Next:

  • Write your message here and send it to us